Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof Nailing 

Permit Number - TC-MDP-0524-00552

Inspection Description - COT - RSBU - Roof Nailing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
10/23/2024 COT - RSBU - Roof Nailing  Re-inspection required 10/23/24: STHD 14 holdown at entry is compromised, shearwall fasteners not per plans, anchor bolt spacing greater than 6', STOPPED INSPECTION MORE ITEMS MAY BE ADDED.
10/24/2024 COT - RSBU - Roof Nailing  Re-inspection required 10/23/24: STHD 14 holdown at entry is compromised, shearwall fasteners not per plans, anchor bolt spacing greater than 6', STOPPED INSPECTION MORE ITEMS MAY BE ADDED.
10/24/24: shear wall fasteners not per plan, back porch not framed per plan missing studs, anchor bolts required at back porch columns, washer plates required at shearwalls, rsp4 required at bearing walls interior, properly secure HTT4, shot pins required throughout interior walls, anchor bolts shall be properly installed on sill plate, truss shall be 3" from edge of any split at top plate, shims required at interior bearing walls that are not making full contact with truss, shims required at cripple studs over window in dining room .
10/28/2024 COT - RSBU - Roof Nailing  Re-inspection required 10-28-24, missing anchor bolt on left side of garage near entry way, add nails to roof in master bath, missing bracing at truss G3510-D, missing nails on several A-34'S on south wall garage area. Stopped inspection-additional items may be added.
11/01/2024 COT - RSBU - Roof Nailing  Passed