Inspection History Details
Inspection Status: Partial Pass
Inspection History: COT - LCEL - Electrical Final
Permit Number - TC-MDP-0523-01101
Inspection Description - COT - LCEL - Electrical Final
Inspection Status - Partial Pass
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/25/2024 | COT - LCEL - Electrical Final | Partial Pass | Partial pass. 1st tower east of building #1. Unit 1205. Provide GFCI receptacle at kitchen counter right of stove. 7/25/2024 |
|
07/26/2024 | COT - LCEL - Electrical Final | Partial Pass | Partial pass. 2nd tower west of building #1. Approved. 7/26/2024 | |
07/29/2024 | COT - LCEL - Electrical Final | Re-inspection required | 7/29/24: GFCI receptacle required for dishwasher. Unit 2101 exterior GFCI receptacle onside circuit as exterior lighting. | |
07/30/2024 | COT - LCEL - Electrical Final | Partial Pass | 7/30/2024. Corrections were made. Tower 4 completed. North end of building 1. Pending roof inspection. | |
07/31/2024 | COT - LCEL - Electrical Final | Re-inspection required | Partial pass. 1st tower east of building #1. Unit 1205. Provide GFCI receptacle at kitchen counter right of stove. 7/25/2024 Partial pass. 2nd tower west of building #1. Approved. 7/26/2024 7/29/24: GFCI receptacle required for dishwasher. Unit 2101 exterior GFCI receptacle onside circuit as exterior lighting. 7/30/2024. Corrections were made. Tower 4 completed. North end of building 1. Pending roof inspection. 7/31/24: properly support refrigerant lines throughout roof, WR receptacles required at roof, refrigerant lines must be uv coated, ensure all dampers at dryer exhaust are functional, roof drains must properly drain away from footings. Refrigerant caps missing throughout at condenser units at roof. |
|
08/01/2024 | COT - LCEL - Electrical Final | Passed |