Inspection Status: Passed
Inspection History: COT - RSBU - Interior Shear BracingĀ
| Date |
Description |
Inspector |
Results |
Comments |
| 04/04/2025 |
COT - RSBU - Interior Shear BracingĀ |
|
Passed |
|
| 07/16/2024 |
COT - RSBU - Interior Shear BracingĀ |
|
Re-inspection required |
7/16/24: properly fasten all H2.5 clips throughout, A35 clips required at x-bracing, properly secure interior walls at top plate and bottom plate, exterior sheathing not fastened per schedule throughout, roof sheathing not fastened per schedule throughout, |