Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-MDP-0523-01087

Parcel: 10612087B


Addresses:

1638 W HIGGINS LN

Inspection Status: Passed

Inspection History: COT - RSBU - Interior Shear BracingĀ 

Date Description Inspector Results Comments
04/04/2025 COT - RSBU - Interior Shear BracingĀ  Passed
07/16/2024 COT - RSBU - Interior Shear BracingĀ  Re-inspection required 7/16/24: properly fasten all H2.5 clips throughout, A35 clips required at x-bracing, properly secure interior walls at top plate and bottom plate, exterior sheathing not fastened per schedule throughout, roof sheathing not fastened per schedule throughout,