Inspection Status: Passed
Inspection History: COT - RSBU - Preslab
Permit Number - TC-MDP-0523-01062
Inspection Description - COT - RSBU - Preslab
Inspection Status - Passed
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/19/2024 | COT - RSBU - Preslab | Passed | Footing are properly dug per plan, shear wall clips are attached to form work, rebar reinforcement is installed where required, rebar for Ufer ground is in place at bottom of footing, post tension cabling is properly installed and supported off the ground, and underground electrical conduit is installed for kitchen island. Okay to pour concrete for slab and footings. |