| 11/16/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | 11/16/23: install mud ring for Ufer, support duct with straps, low air test on gas pipe, block hole in garage shear wall, duct not run to west bedroom/den, run bathroom exhaust duct over the top of ABS, jump duct missing in east bedroom, block ends of register box. INSPECTION STOPPED. MORE ITEMS MAYBE ADDED AT NEXT INSPECTION. | |
| 11/22/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | 11/16/23: install mud ring for Ufer, support duct with straps, low air test on gas pipe, block hole in garage shear wall, duct not run to west bedroom/den, run bathroom exhaust duct over the top of ABS, jump duct missing in east bedroom, block ends of register box. INSPECTION STOPPED. MORE ITEMS MAYBE ADDED AT NEXT INSPECTION. 11/22/23: support all duct with straps, relocate hall fresh air intake register, duct interferes with 30" required clear head space at shuttle opening. |
|
| 12/06/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 12/6/23:intermediate approved | |
| COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | passed per previous inspector |