Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof Nailing 

Permit Number - TC-MDP-0523-01040

Inspection Description - COT - RSBU - Roof Nailing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
09/21/2023 COT - RSBU - Roof Nailing  Re-inspection required 9/21/23 rsp clips missing first floor, h25 clips needs nails second floor. First floor shear walls missing anchor bolts
09/25/2023 COT - RSBU - Roof Nailing  Passed