Inspection Status: Re-inspection required
Inspection History: COT - RSPL - Gas Pressure Test
| Date |
Description |
Inspector |
Results |
Comments |
| 10/26/2023 |
COT - RSPL - Gas Pressure Test |
|
Re-inspection required |
nail plate needed left side of garage, dwv not under test, no plans on site, support copper pipe behind bathtub, support duct registers on three sides, nail plates missing throughout, foam missing at top plate in dining room, missing plumbing cleanouts, revise plans to show current plumbing layout of house and provide by final, pex lines must be insulated or at least 12” away from can lights, connect duct at furnace, gas not under pressure. |
| 10/27/2023 |
COT - RSPL - Gas Pressure Test |
|
Passed |
|