Inspection Status: Re-inspection required
Inspection History: COT - RSEL - Electrical Final
| Date |
Description |
Inspector |
Results |
Comments |
| 03/07/2024 |
COT - RSEL - Electrical Final |
|
Re-inspection required |
Refrigerant line at A/C must be wrapped with UV rated tape, cooking appliances shall have a vertical clearance above cooking stop/range no less than 30” to combustible material. No less than 24” to non-combustible listed materials per G2447.5, countertop to left of range missing outlet per E3901.4, complete wiring in laundry room, water on floor at master bathroom toilet. |
| 03/14/2024 |
COT - RSEL - Electrical Final |
|
Passed |
|