Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSEL - Electrical Final
Permit Number - TC-MDP-0523-00994
Inspection Description - COT - RSEL - Electrical Final
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/07/2024 | COT - RSEL - Electrical Final | Re-inspection required | Refrigerant line at A/C must be wrapped with UV rated tape, cooking appliances shall have a vertical clearance above cooking stop/range no less than 30” to combustible material. No less than 24” to non-combustible listed materials per G2447.5, countertop to left of range missing outlet per E3901.4, complete wiring in laundry room, water on floor at master bathroom toilet. | |
03/14/2024 | COT - RSEL - Electrical Final | Passed |