Inspection Status: Re-inspection required

Inspection History: COT - RSPL - Plumbing Final 

Permit Number - TC-MDP-0523-00994

Inspection Description - COT - RSPL - Plumbing Final 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
03/07/2024 COT - RSPL - Plumbing Final  Re-inspection required Refrigerant line at A/C must be wrapped with UV rated tape, cooking appliances shall have a vertical clearance above cooking stop/range no less than 30” to combustible material. No less than 24” to non-combustible listed materials per G2447.5, countertop to left of range missing outlet per E3901.4, complete wiring in laundry room, water on floor at master bathroom toilet.
03/14/2024 COT - RSPL - Plumbing Final  Passed