Inspection Status: Re-inspection required
Inspection History: COT - RSEL - Electrical Final
Permit Number - TC-MDP-0523-00993
Inspection Description - COT - RSEL - Electrical Final
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/07/2024 | COT - RSEL - Electrical Final | Re-inspection required | Last breaker missing labeling at dead front, EV charger installation not complete, no water going to house, kitchen outlets must be gfci protected, cooking appliances shall have vertical clearance above cooking stop/range no less than 30” to combustible material. No less than 24” to non-combustible listed materials per G2447.5, refrigerator must run on its own circuit, countertop to right of range missing outlet per E3901.4. STOPPED INSPECTION. More items may be added. | |
03/14/2024 | COT - RSEL - Electrical Final | Passed |