Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 08/29/2023 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
Not ready. Anchor bolts not per shear wall schedule. Extend attic platform. Missing king studs at garage. Missing clips at 6x8 and 6x6 post at porch. Missing anchor bolts site due to spacing of masa clips over 6'. Add h25 clips to double girders at the third baring point. Provide truss calcs. 8/29/2023 |
| 09/01/2023 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |
|