| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/18/2023 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 7/18/23: shear wall 11 calls for anchor bolt 23" on center, Shear wall 11 or larger require 3"x3" plate washer, missing anchor bolt on outside perimeter of house, htt4 missing at shear wall 11 in master closet. rsp4 every other stud per plan, rsp5 missing on truss on south end of home | |
| 07/24/2023 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed |