Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - TC-MDP-0523-00985
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/18/2023 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | 7/18/23: shear wall 11 calls for anchor bolt 23" on center, Shear wall 11 or larger require 3"x3" plate washer, missing anchor bolt on outside perimeter of house, htt4 missing at shear wall 11 in master closet. rsp4 every other stud per plan, rsp5 missing on truss on south end of home | |
07/24/2023 | COT - RSBU - Exterior Clips/Sheathing | Passed |