Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-0523-00985

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
07/18/2023 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required 7/18/23: shear wall 11 calls for anchor bolt 23" on center, Shear wall 11 or larger require 3"x3" plate washer, missing anchor bolt on outside perimeter of house, htt4 missing at shear wall 11 in master closet. rsp4 every other stud per plan, rsp5 missing on truss on south end of home
07/24/2023 COT - RSBU - Exterior Clips/Sheathing  Passed