Inspection Status: Re-inspection required
Inspection History: RSBU - Building Final
Permit Number - TC-MDP-0523-00959
Inspection Description - RSBU - Building Final
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/05/2024 | RSBU - Building Final | Re-inspection required | No HCS cap, outlet by fridge must be gfci protected, kitchen island outlets not live, bedroom missing carpet. | |
01/10/2024 | RSBU - Building Final | Re-inspection required | Outlet by fridge must be gfci protected, kitchen island outlets not live. | |
01/16/2024 | RSBU - Building Final | Re-inspection required | No HCS cap, outlet by fridge must be gfci protected, kitchen island outlets not live, bedroom missing carpet. Outlet by fridge must be gfci protected, kitchen island outlets not live. 1/16/24: All exterior PVC-ABS must be coated for UV protection, YWL insulation must be wrapped with UV protection at bottom half, water hammer arrestor missing at dishwasher, dishwasher must be properly drained, drywall repair needed in upstairs bedroom closet. Hose bib needs to be properly fastened. No water pressure in house, exterior sconce needs to be painted. Carpet in first floor bedroom not installed. |
|
01/22/2024 | RSBU - Building Final | Re-inspection required (with fee) | Dishwasher must be properly drained, drywall repair needed in upstairs bedroom closet. Hose bib needs to be properly fastened. No water pressure in house. Re-inspection with fee required. | |
01/24/2024 | RSBU - Building Final | Passed |