Inspection History Details
Inspection Status: Canceled
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
Permit Number - TC-MDP-0523-00958
Inspection Description - COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
Inspection Status - Canceled
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/27/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Canceled | Cancelled per Trent. | |
02/29/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
10/27/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | Foam top plate at low voltage throughout, support duct registers on all 3 sides throughout, pex lines must be 12" away from can lights or must be insulated, support 4gang box, staple wire needed by front door, missing clean outs at second floor. Add clean outs or revise plans to show current layout of plumbing, provide updated city stamped plans with no clean outs at final. | |
10/30/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | Foam top plate at low voltage throughout, support duct registers on all 3 sides throughout, pex lines must be 12" away from can lights or must be insulated, support 4gang box, staple wire needed by front door, missing clean outs at second floor. Add clean outs or revise plans to show current layout of plumbing, provide updated city stamped plans with no clean outs at final. | |
11/01/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Partial Pass | Missing clean outs at second floor. Add clean outs or revise plans to show current layout of plumbing, provide updated city stamped plans with no clean outs at final. Proceed at risk. |