Permit: TC-MDP-0523-00948

Parcel: 12913440A

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
04/22/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 4/22/25: Anchor bolts required 12" from edge of sill plate, anchor bolt spacing shall be no greater than 48" o.c, H2.5 clips missing from truss to double top plate, shot pins required 4" from edge of bottom plate at interior walls, blocking required at fire wall.
04/25/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed