Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Interior Shear BracingĀ 

Date Description Inspector Results Comments
11/02/2026 COT - RSBU - Interior Shear BracingĀ  Re-inspection required 11/2/26: provide approved set of plans, missing screws at base of powder room, missing screws along base underneath stairs, add additional screws where screws are installed closer than 3/8" from edges or joints (primarily at stairs and bedrooms-have tapers check throughout), missing section drywall at 2nd floor behind tub, closet at upstairs south bedroom requires additional screws along edges. Re-schedule at your convenience.
11/03/2026 COT - RSBU - Interior Shear BracingĀ  Passed Corrections were made. 11/3/2026