Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 8-5-26: add anchor bolts to marked areas, add nails 8" o.c.at marked locations at windows, add shot pins to non load bearing and shear walls per SN2 Note5/Schedule, plans call for 3kings/1 trimmer at garage entryway, see detail 303 options and install per options. Stopped inspection-additional items may be noted. | ||
| 08/10/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 8-10-26: did not walk inspection due to trades working on site. Reschedule inspection. | |
| 08/11/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 08/11/2026 Corrections made, walked rest of building. |