Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Permit Number - TC-MDP-0425-00277
Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/22/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 9.22.25 Seat or shim floating truss at 2nd floor as marked Replace or sister damaged studs at marked locations on 2nd and 1st floor Replace or remedy per manufacturer t ply at first floor as marked. Over penetration, improper spacing, and minor damage throughout Add anchor bolts as marked throughout |
|
| 09/24/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed |