Parcel: 141461020


Addresses:

9650 E FRIEDEL DR


Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Permit Number - TC-MDP-0425-00277

Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
09/22/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 9.22.25
Seat or shim floating truss at 2nd floor as marked

Replace or sister damaged studs at marked locations on 2nd and 1st floor

Replace or remedy per manufacturer t ply at first floor as marked. Over penetration, improper spacing, and minor damage throughout

Add anchor bolts as marked throughout
09/24/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed