Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Roof Nailing
Permit Number - TC-MDP-0425-00276
Inspection Description - COT - RSBU - Roof Nailing
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/26/2025 | COT - RSBU - Roof Nailing | Re-inspection required | 1. Glulam not per plan in Garage, too big. Provide engineer letter for supports. 2. Broken truss in garage southeast, truss CJO1 and J02. Provide engineer letter. 3. Broken truss 2nd floor just above stairs marked on the floor in blue ink. 4. Broken cripple stud under window. 5. A35s missing under stairs on each stringer. 6. Awaiting Truss layout. 7. 2nd floor shear walls nailing not per plan on corners. 4” o.c. per plan. 8. Ok to dry roof. |
|
| 10/14/2025 | COT - RSBU - Roof Nailing | Re-inspection required (with fee) | 10/14/25 All items above from previous have not been accomplished, with the exception of item 7. Next inspection will require a re-inspection fee. |
|
| 11/07/2025 | COT - RSBU - Roof Nailing | Passed | 11.07.2025 Approved per plan, verify before drywall the engineer letter/fix of truss in second floor near stairs and garage truss. Beam corrected. |