Permit: TC-MDP-0424-00543

Parcel: 140363630


Addresses:

5198 E CARAMBOLA CT

Inspection Status: Re-inspection required

Inspection History: RSBU - Building Progress

Date Description Inspector Results Comments
08/22/2024 RSBU - Building Progress Re-inspection required 8/22/24: post tension tag required at hose bib, insulation required on exterior hose bib, 3" clearance required at A/C condenser form grade, properly secure electrical whip at A/C condenser, anti-corrosion compound required at aluminum conductors, no power at A/C unit, no plans at time of inspection, A.V.V must be above flood rim level, secure NM cable 12" from box at attic receptacle, clean out missing at kitchen sink.
08/27/2024 RSBU - Building Progress Passed