Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Excavation/Rebar/Zoning
Permit Number - TC-MDP-0424-00525
Inspection Description - COT - RSBU - Excavation/Rebar/Zoning
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/11/2024 | COT - RSBU - Excavation/Rebar/Zoning | Re-inspection required | 6/11/24: rebar at interior footings not to schedule. Rebar at interior corners top and bottom should bend around corners | |
06/12/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 6/12/24: Rebar reinforcement has been corrected to meet plans. Concrete forms are set, post tension cabling is properly installed and evenly spaced, rebar reinforcement is in place per plans, masa clips and shear wall hold downs are properly secured to form, subsoil is compacted, underground plumbing is properly wrapped with foam, underground electrical is installed for kitchen island, and Ufer ground is installed in footing on garage side of house. |