Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 141460500


Addresses:

9692 E HARKES DR


Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Preslab  

Permit Number - TC-MDP-0424-00525

Inspection Description - COT - RSBU - Preslab  

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
06/11/2024 COT - RSBU - Preslab   Re-inspection required 6/11/24: rebar at interior footings not to schedule. Rebar at interior corners top and bottom should bend around corners
06/12/2024 COT - RSBU - Preslab   Passed 6/12/24: Rebar reinforcement has been corrected to meet plans. Concrete forms are set, post tension cabling is properly installed and evenly spaced, rebar reinforcement is in place per plans, masa clips and shear wall hold downs are properly secured to form, subsoil is compacted, underground plumbing is properly wrapped with foam, underground electrical is installed for kitchen island, and Ufer ground is installed in footing on garage side of house.