Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - TC-MDP-0424-00523
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/01/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | Add anchor bolts to those that are out of center 3rd. Loose shear walls second floor. Nailing not per schedule at shear walls second floor. Re nail perimeter at second floor bottom plates. 7/1/2024 | |
07/03/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | 7/3/24: anchor bolts have been added to those areas that are out of center 3rd of bottom plate. Plywood on second floor has been properly nailed off. Bottom plate has been nailed along perimeter at second floor. |