Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 141460420


Addresses:

9628 E HARKES DR


Inspection Status: Re-inspection required

Inspection History: RSBU - Building Final 

Permit Number - TC-MDP-0424-00517

Inspection Description - RSBU - Building Final 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
05/06/2025 RSBU - Building Final  Re-inspection required Missing smoke detector in bedroom. Dishwasher not secured and incomplete. Extend handrail. Missing noalax at aluminum conductors at a.c disconnect. Provide labeling at panel of non metallic plumbing. Provide post tension tag. Missing label at garage door. Tighten hinges. 5/6/2025
05/09/2025 RSBU - Building Final  Passed 5/8/25 corrections made