Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - TC-MDP-0424-00500
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/25/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | 7/25/24: cut nails needed at bottom plates at pantry and in master bed room. Missing anchor bolts at shear wall at garage. Add anchor bolts where excessive masa clips legs are up. Missing rsp clips on north side of home | |
07/29/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | 7/29/24: Shot pins have been installed on bottom plate of the pantry and master bedroom. Titan bolts added at garage shear wall and at locations where masa clips were nailed to studs and not bottom plate. RSP clips have been installed on north side of house. Okay to proceed with rough-in. |