Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-0424-00500

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
07/25/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required 7/25/24: cut nails needed at bottom plates at pantry and in master bed room. Missing anchor bolts at shear wall at garage. Add anchor bolts where excessive masa clips legs are up. Missing rsp clips on north side of home
07/29/2024 COT - RSBU - Exterior Clips/Sheathing  Passed 7/29/24: Shot pins have been installed on bottom plate of the pantry and master bedroom. Titan bolts added at garage shear wall and at locations where masa clips were nailed to studs and not bottom plate. RSP clips have been installed on north side of house. Okay to proceed with rough-in.