Inspection Status: Passed
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 01/07/2025 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |
1/7/25 corrections made |
| 12/19/2024 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
12-19-24, shear walls not per schedule; missing nails in several areas throughout & over penetrated. See chapter 6 of the IRC for details. Loose anchor bolts throughout, several A-35's are missing nails or are not nailed flush to top plate. STOPPED INSPECTION, ADDITIONAL ITEMS MAY BE NOTED. |