Inspection Status: Passed
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
| Date |
Description |
Inspector |
Results |
Comments |
| 02/21/2025 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
|
Passed |
2/21/25 pass |
| 11/12/2024 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
|
Re-inspection required |
11-12-24, pancake metal exterior box near garage is overfilled. Box is rated for 6 cubic inches and contains 2 14/2 awg wires, panel not per approved plans. Provide a letter from Austin electric company together with a schematic of actual electrical wiring and submit for review. Approval is required before certificate of occupancy can be issued. |
| 11/14/2024 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
|
Partial Pass |
11-14-24, correction to pancake box made. Okay to proceed at own risk. See previous notes. |