Date Description Inspector Results Comments
08/08/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required 8/8/24: lsthd8 not installed in garage. Missing continuous nailer at top web at front porch. Missing anchor bolts where excessive masa legs are up. Missing nailing at rsp clips throughout. Cut nails needle at interior bedrooms west side of home.
08/15/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required 8/15/24: add nailing to rsp clips front of home. Missing cut nails at bottom plate bedroom front of home. Sthd10 needs to be installed or replaced with equivalent hold down in garage
COT - RSBU - Exterior Clips/Sheathing  Passed