Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - TC-MDP-0424-00425
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/08/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | 8/8/24: lsthd8 not installed in garage. Missing continuous nailer at top web at front porch. Missing anchor bolts where excessive masa legs are up. Missing nailing at rsp clips throughout. Cut nails needle at interior bedrooms west side of home. | |
08/15/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | 8/15/24: add nailing to rsp clips front of home. Missing cut nails at bottom plate bedroom front of home. Sthd10 needs to be installed or replaced with equivalent hold down in garage | |
COT - RSBU - Exterior Clips/Sheathing | Passed |