Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
| Date |
Description |
Inspector |
Results |
Comments |
| 09/18/2024 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
|
Re-inspection required |
Missing ground screw to pancake boxes. Secure 8 awg in great room ceiling. Add receptacle in study room. Add receptacle in bedroom 2 per 6' from door. Secure blue cable at master bedroom. Smoke in hallway near bedroom 4 no wired. Staple punctured in ABS pipe laundry room. 9/18/2024 |
| 09/20/2024 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
|
Re-inspection required |
Missing ground screw to pancake boxes. Secure 8 awg in great room ceiling. Add receptacle in study room. Add receptacle in bedroom 2 per 6' from door. Secure blue cable at master bedroom. Smoke in hallway near bedroom 4 no wired. 9/20/2024 |
| 09/24/2024 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
|
Passed |
Corrections were made. 9/24/2024 |