Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - TC-MDP-0424-00396
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/27/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | Missing 2x at FLOOR GT. Sister 2x6 at 2x that's been compromised in great room area near window. Add anchor bolts per shear wall schedule. Add blocking at landings. Header at at bedroom 2 along with studs not per plan. Provide RFI on engineer fix on truss A03A. Missing attic access. RFI on window option in loft/bedroom 4. STOPPED INSPECTION. 8/27/2024 | |
08/30/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | Missing 2x at FLOOR GT. Sister 2x6 at 2x that's been compromised in great room area near window. Add anchor bolts per shear wall schedule. Add blocking at landings. Header at at bedroom 2 along with studs not per plan. Provide RFI on engineer fix on truss A03A. Missing attic access. RFI on window option in loft/bedroom 4. STOPPED INSPECTION. 8/27/2024 8/30/24: corrections pending |
|
09/09/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | 9/9/2024 corrections were made. Approved. |