Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Roof Nailing
Permit Number - TC-MDP-0424-00396
Inspection Description - COT - RSBU - Roof Nailing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/27/2024 | COT - RSBU - Roof Nailing | Re-inspection required | Missing 2x at FLOOR GT. Sister 2x6 at 2x that's been compromised in great room area near window. Add anchor bolts per shear wall schedule. Add blocking at landings. Header at at bedroom 2 along with studs not per plan. Provide RFI on engineer fix on truss A03A. Missing attic access. RFI on window option in loft/bedroom 4. STOPPED INSPECTION. 8/27/2024 | |
08/30/2024 | COT - RSBU - Roof Nailing | Re-inspection required | Missing 2x at FLOOR GT. Sister 2x6 at 2x that's been compromised in great room area near window. Add anchor bolts per shear wall schedule. Add blocking at landings. Header at at bedroom 2 along with studs not per plan. Provide RFI on engineer fix on truss A03A. Missing attic access. RFI on window option in loft/bedroom 4. STOPPED INSPECTION. 8/27/2024 8/30/24: corrections pending |
|
09/09/2024 | COT - RSBU - Roof Nailing | Passed | 9/9/2024 corrections were made. Approved. |