Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
08/30/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required Workers in house.
09/01/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required Workers in house.

9/1/23: missing anchor bolts throughout ( spacing is either larger than 6', more than one masa clip with 1 leg up continuous, masa with two legs up or not set properly). Anchor bots at shear wall 6 need to be no more than 32" O.C, back porch 5 1/8" X 16 1/2 GLB requires 2-2x6 at each end for support. Gutter truss in dinning room needs to be continuously supported with 2-2x4 (missing under window), RSP4 clips per plan are required every other stud
10/04/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed