Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/30/2023 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | Workers in house. | |
| 09/01/2023 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | Workers in house. 9/1/23: missing anchor bolts throughout ( spacing is either larger than 6', more than one masa clip with 1 leg up continuous, masa with two legs up or not set properly). Anchor bots at shear wall 6 need to be no more than 32" O.C, back porch 5 1/8" X 16 1/2 GLB requires 2-2x6 at each end for support. Gutter truss in dinning room needs to be continuously supported with 2-2x4 (missing under window), RSP4 clips per plan are required every other stud |
|
| 10/04/2023 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed |