Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - TC-MDP-0423-00899
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/07/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | 3/7/24: Anchor bolt spacing at shear wall 13 greater than 17" o.c, Anchor bolts at shear wall 11 or greater require 3"x3" plate washer (missing throughout), shear wall fastening schedule not per plan throughout, shear walls up stairs need to be fastened per schedule at bottom plate throughout. | |
03/12/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed |