Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Permit Number - TC-MDP-0423-00896

Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
07/09/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 7/9/24: missing straps/clips at headers at back of house 1st and 2nd floor. Missing anchor bolts at shear walls throughout. Missing anchor bolts where excessive legs are up at masa clips. Sheathing at shear wall in master bathroom loose. Missing lateral bracing.
07/12/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 7/12/24: Straps and clips have been installed at headers in rear of house. Anchor bolts have been installed on shear walls. Lateral bracing has been installed where needed. Sheathing has been secured to studs in master bedroom shear wall.