09/11/2023 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Pending broken truss. A3520. Provide engineer fix. Add straps at garage openings. Add anchor bolts at shear wall in bedroom 3 per schedule. Add straps at sliding glass door. Add h25 at bearing walls. 9/11/2023
COT - RSBU - Exterior Clips/Sheathing  Passed 9/26/23: all corrections made