Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - TC-MDP-0423-00891
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/11/2023 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | Pending broken truss. A3520. Provide engineer fix. Add straps at garage openings. Add anchor bolts at shear wall in bedroom 3 per schedule. Add straps at sliding glass door. Add h25 at bearing walls. 9/11/2023 | |
COT - RSBU - Exterior Clips/Sheathing | Passed | 9/26/23: all corrections made |