09/11/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Partial Pass Partial pass. Missing king studs on both ends at sliding glass door. Missing h25 clips at garage entry and 3rd bedroom. Nail off h25 clips at great room. Add blocking to register at laundry room. 9/11/2023
09/14/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed