Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - TC-MDP-0423-00862
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/18/2023 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | 7/18/23: all trimmers supporting headers are required to be continuous from base plate to bottom of header without breaks or hinge points. All openings are required to have a minimum of one king stud at each end that supports the trimmer stud, and this king stud is to be continuous plate to plate. | |
07/20/2023 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | ||
07/21/2023 | COT - RSBU - Exterior Clips/Sheathing | Passed |