Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Permit Number - TC-MDP-0423-00862
Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/18/2023 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 7/18/23: all trimmers supporting headers are required to be continuous from base plate to bottom of header without breaks or hinge points. All openings are required to have a minimum of one king stud at each end that supports the trimmer stud, and this king stud is to be continuous plate to plate. | |
| 07/20/2023 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | ||
| 07/21/2023 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed |