Inspection Status: Re-inspection required
Inspection History: BULD - Electrical Clearance
Permit Number - TC-MDP-0423-00842
Inspection Description - BULD - Electrical Clearance
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/12/2023 | BULD - Electrical Clearance | Re-inspection required | 7/12/23: Bond ufer and rebar together with clamp, seal penetration going through top plate at garage, nail plate stud at back end of garage and at gathering room, dwv not under test, insulate pex that is within 12" of can lights, secondary condensate line double trapped, staple wires at bedroom 2. | |
07/13/2023 | BULD - Electrical Clearance | Re-inspection required | 7/12/23: Bond ufer and rebar together with clamp. | |
07/14/2023 | BULD - Electrical Clearance | Passed |