Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSEL - Grounding/Bonding
Permit Number - TC-MDP-0423-00842
Inspection Description - COT - RSEL - Grounding/Bonding
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/12/2023 | COT - RSEL - Grounding/Bonding | Re-inspection required | 7/12/23: Bond ufer and rebar together with clamp, seal penetration going through top plate at garage, nail plate stud at back end of garage and at gathering room, dwv not under test, insulate pex that is within 12" of can lights, secondary condensate line double trapped, staple wires at bedroom 2. | |
07/13/2023 | COT - RSEL - Grounding/Bonding | Re-inspection required | 7/12/23: Bond ufer and rebar together with clamp. | |
07/14/2023 | COT - RSEL - Grounding/Bonding | Passed |