Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Passed

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-0423-00831

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Passed

Date Description Inspector Results Comments
05/22/2023 COT - RSBU - Exterior Clips/Sheathing  Passed H2.5 clips are on all rafters. Shear wall brackets are properly installed. Shear wall anchor bolts have proper washers on them. Okay to prep for exterior stucco finish.