Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Permit Number - TC-MDP-0423-00829

Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
06/14/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 6/14/23: exterior anchor bolts missing where M.A.S.A clips have 2 legs up or have continuous M.A.S.A clips with 1 leg up.
06/17/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed