Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Preslab
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/14/2026 | COT - RSBU - Preslab | Re-inspection required | 07/14/2026 Foam wrap plastic ABS in garage footing, heavy rain in trench along east wall footing and rear patio. |
|
| 07/15/2026 | COT - RSBU - Preslab | Re-inspection required (with fee) | 7/15/26: per previous notes, rebar reinforcement shall be no closer than 3" from earth @ UFER ground, plumbing at garage has not been wrapped, properly support reinforcement at hold-downs, end caps required at stationary ends, footings shall be 12"x12", clean out footings of debris. Re-inspection required with fee. | |
| 07/17/2026 | COT - RSBU - Preslab | Passed |