Inspection Status: Re-inspection required
Inspection History: COT - RSME - Mechanical FinalĀ
| Date |
Description |
Inspector |
Results |
Comments |
| 10/12/2026 |
COT - RSME - Mechanical FinalĀ |
|
Re-inspection required |
10/12/26: pending conditions, bus bar at cox communication at panel (missing ground), Laundry room shall be AFCI/GFCI, Refrigerator requires AFCI/GFCI, exterior plastic piping must be coated for uv protection, secure door bell, remove paint from garage door fire rated tag, remove covers from smoke detectors, remove paint from water hammer arrestor, master bath plumbing incomplete, attic access requires 30" of headroom clearance, torn flex in attic behind air handler, properly secure flex duct near attic opening, air handler is over amped |