Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Partial Pass
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Permit Number - TC-MDP-0325-00204
Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Inspection Status - Partial Pass
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/25/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Partial Pass | 7/25/25 1. In Garage roof, Broken web on Truss (4)G2 about 4" from gusset plate. 2. In Garage roof, Cracked/splitting Top chord and web in Truss(2) G2 see marking on stud. 3. Anchor bolt missing on the NE wall just after garage, marked an X on the sill. |
|
| 08/15/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 8.15.25 Corrections made |