Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
Permit Number - TC-MDP-0325-00180
Inspection Description - COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/06/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | 6/6/25: DWV not under test, seal all penetrations throughout vapor barrier, 16 gauge x1.5" strap required at over notched top plate at closet first floor, anchor bolts required at garage east shearwall, seal sleeve at kitchen island, support NM cable at kitchen pantry 48"o.c, NM cable must be properly supported from receptacle boxes, DWV requires mid way strap in wall, fresh air intake must be 10' from vent, condensate drain must be properly pitched. STOPPED INSPECTION MORE ITEMS MAY BE ADDED (only north half of 2nd story was walked). | |
| 06/10/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | 6-10-25: firefoam penetrations at sill plate in master suite, seal vapor barrier at marked locations in garage, attach Boca plate to sill plate at east wall at great room and at upstairs for DWV at loft, DWV including shower must be under test, firefoam chute at upstairs master bathroom, connect future solar mc cable to junction box at upstairs laundry room, fresh air intake shall not be closer than 10' from any vents or fresh air intake, fix tear on flex at great room, secure light with bracing at kitchen area. | |
| 06/12/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 6-12-25: intermediates approved. |