Inspection History: COT - RSBU - Interior Shear Bracing 

Date Description Inspector Results Comments
02/02/2026 COT - RSBU - Interior Shear Bracing  Re-inspection required 2-2-26: add nails at sheathing where closer than 3/8" from joints and where nails over penetrate more than 1/16" ( I did not mark exterior sheathing-have framers walk and add nails per notes). Add a/b's 24" o.c. At Fire wall and shot pins at interior framing- 24" o.c..., missing A34's cross bracing-required at top & bottom, add anchor bolt to marked location at south wall, add bracing at restrooms-see plans for details.
02/02/2026 COT - RSBU - Interior Shear Bracing  Re-inspection required 2-2-26: no plans on site.
02/03/2026 COT - RSBU - Interior Shear Bracing  Partial Pass 2-3-26: partial pass on firewall. Okay to tape & texture one side and install drywall on other.
04/28/2026 COT - RSBU - Interior Shear Bracing  Passed