Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-MDP-0324-00351

Parcel: 103193040


Addresses:

2344 W OWL PERCH LP

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Preslab  

Date Description Inspector Results Comments
06/06/2024 COT - RSBU - Preslab   Re-inspection required 6/6/24: reinforcement requires 3" clearance from earth (making contact throughout), PT pocket former not properly installed at garage, exposed cable at PT over the maximum allowable throughout on both ends. Footings must be 12" in depth,
06/07/2024 COT - RSBU - Preslab   Passed Corrections were made. Okay for concrete placement. 6/7/2024