Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 09/06/2024 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
Add anchor bolts per shear wall schedule and at other marked areas. Loose shear left of SGD. Missing a35 clips at corners underneath landings. Loose shear wall 2nd floor marked area. Add nails to exterior bottom plates. 9/6/2024 |
| 09/10/2024 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |