Parcel: 141450250


Addresses:

6561 E PASEO ALGA


Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Permit Number - TC-MDP-0324-00343

Inspection Description - COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
10/16/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required Lath incomplete. Water lines and DWV not on test. Add nail plates to both electrical and plumbing lines that are less than an 1 1/4". Light in kitchen ceiling not made up. Remove electrical lines from gusset plates. Shower pan and tub not on test. Seal all exterior and penetrations through top plates. Missing receptacle in bedroom 4 under switch. Add receptacle in both 2 and 3 bedrooms. Wall greater than 2'. 10/16/2024
10/21/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Canceled 10-21-24, cancelled per Phil.
10/23/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required Lath incomplete. Water lines and DWV not on test. Add nail plates to both electrical and plumbing lines that are less than an 1 1/4". Light in kitchen ceiling not made up. Remove electrical lines from gusset plates. Shower pan and tub not on test. Seal all exterior and penetrations through top plates. Missing receptacle in bedroom 4 under switch. Add receptacle in both 2 and 3 bedrooms. Wall greater than 2'. 10/16/2024
10-23-24, provide set of approved plans. Noted upstairs DWV has a water leak coming from lavatory located in north wall.
10/25/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 10-25-24, listed items from previous inspection corrected. Intermediates approved, okay to proceed with build.