Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Re-inspection required
Inspection History: BULD - Electrical Clearance
| Date |
Description |
Inspector |
Results |
Comments |
| 10/03/2024 |
BULD - Electrical Clearance |
|
Re-inspection required |
10/3/24: Thermostat shall be no higher than 54" above finish grade, strap required at living room GLB, pex requires 12" clearance from can light, kitchen hood duct must be properly installed in wall, block registers on three sides at entrance, secure NM cable. 12" from fixture, seal penetrations at vapor barrier. Properly secure Ufer ground |
| 10/07/2024 |
BULD - Electrical Clearance |
|
Passed |
Clearance for TEP ECO. 10/7/2024 |